| NIBE
Fighter Air Source Heat Pump |
Single
Phase
2015-6 |
Single
Phase
2015-8 |
Single
Phase
2015-11 |
| Heat Pump Delivered/Supplied
Power* at 2/35°C ** |
5.4 / 1.4 KW |
7.1 / 1.8 KW |
9.4 / 2.6 KW |
| Heat Pump Delivered/Supplied Power* at 7/35°C
** |
6.3 / 1.4 KW |
8.2 / 1.9 KW |
11.1 / 2.6 KW |
| Heat Pump Delivered/Supplied
Power* at -7/45°C ** |
3.7 / 1.6 KW |
5.0 / 2.1 KW |
7.1 / 2.9 KW |
| Heat Pump Delivered/Supplied Power* at 0/45°C
** |
4.9 / 1.6 KW |
6.4 / 2.1 KW |
8.8 / 3.1 KW |
| Heat Pump Delivered/Supplied
Power* at 7/45°C ** |
6.0 / 1.7 KW |
7.8 / 2.2 KW |
10.9 / 3.2 KW |
| Heat Pump Delivered/Supplied Power* at -7/50°C
** |
3.6 / 7.1 KW |
4.9 / 2.3 KW |
7.1 / 3.2 KW |
| Heat Pump Delivered/Supplied
Power* at 2/50°C ** |
5.0 / 1.8 KW |
6.6 / 2.4 KW |
9.2 / 3.4 KW |
| Heat Pump Delivered/Supplied Power* at 7/50°C
** |
5.9 / 1.8 KW |
7.6 / 2.4 KW |
10.8 / 3.6 KW |
| Heat Pump Delivered/Supplied
Power* at 15/50°C ** |
7.2 / 1.9 KW |
9.2 / 2.4 KW |
12.8 / 3.6 KW |
| Starting Current |
17 A |
19 A |
27 A |
| Motor Protection Setting |
14 A |
18 A |
22 A |
| Soft Start Relay |
As Standard |
As Standard |
As Standard |
| Operating Voltage |
230v + N + PE 50 Hz |
230v + N + PE 50 Hz |
230v + N + PE 50 Hz |
| Compressor |
Scroll Compressor |
Scroll Compressor |
Scroll Compressor |
| Nominal flow heating
medium |
0.16 l/s |
0.20 l/s |
0.25 l/s |
| Internal pressure drop at nominal flow |
1.3 kPa |
1.5 kPa |
2.2 kPa |
| Air Flow |
1500 m³/h |
1700/2000 m³h |
1700/2000 m³h |
| Nominal output fan |
70 W |
90/130 W |
90/130 W |
| Fuse |
10 A |
10 A |
16 A |
| Enclosure Cla |
IP 24 |
IP 24 |
IP 24 |
| Max outgoing heating
medium temperature |
58° C |
58° C |
58° C |
| Refrigerant quantity (R407C) |
1.9 kg |
2.1 kg |
2.1 kg |
| Connecting heating
medium male diametre |
G1(Ø 28 mm) |
G1(Ø 28 mm) |
G1(Ø 28 mm) |
| Defrosting System |
hot gas defrosting |
hot gas defrosting |
hot gas defrosting |
| Cut-out value pressotat
HP |
29 bar |
29 bar |
29 bar |
| Cut-out value pressotat LP |
0.3 bar |
0.3 bar |
0.3 bar |
| Difference pressotat
HP |
-7 bar |
-7 bar |
-7 bar |
| Difference pressotat LP |
+ 0.7 bar |
+ 0.7 bar |
+ 0.7 bar |
| Height with stand |
1045mm |
1045mm |
1045 mm |
| Width |
1200mm |
1200mm |
1200mm |
| Depth |
520mm |
520mm |
520mm |
| Weight |
120 kg |
126 kg |
132 kg |
* For compressor, ventilator and control. The
relation between ”heating capacity and receptivity”
must be reduced by approx. 10% during defrosting.
** Outside air temperature/flow temperature