NIBE
1245 Ground Source Heat Pumps
Technical
Overview
NIBE FIGHTER 1245 is a ground source heat pump
for heating single and small multi family homes.
They incorporate a 180 litre hot water cylinder
and immersion boost heaters. You hot water needs
will be assessed by us on system design, with
most 3 - 4 bedroom houses ideally suited for the
1245 ground source heat pump.

Single Phase
| NIBE
Fighter 1245 Ground Source Heat Pump |
5
KW |
8
KW |
12
KW |
| Recorded Capacity*
(Brine O /W 35) |
1.09 KW |
1.73 KW |
2.58 KW |
| Emitted Capacity* (Brine O /W 35) |
4.83 KW |
8.33 KW |
11.88 KW |
| CoP at Brine 0 /W
35 |
4.44 CoP |
4.82 CoP |
4.6 CoP |
| Height |
1475 without adjustable feet (30 - 50mm) |
1475 without adjustable feet (30 - 50mm) |
1475 without adjustable feet (30 - 50mm) |
| Width |
600mm |
600mm |
600mm |
| Depth |
625mm |
625mm |
625mm |
| Net Weight |
140kg |
165kg |
178kg |
| Operating Voltage |
230 V (1-Phase+N) |
230 V (1-Phase+N) |
230 V (1-Phase+N) |
| Intergrated Cartridge
Heater |
7 (7) KW |
7 (7) KW |
7 (7) KW |
| Hot Water Cylinder Volume |
180 Litres |
180 litres |
180 litres |
| Ground Heat, hose
length** |
200-300 m |
325-2X250 m |
2x250 m-2X350 m |
| Borehole Depth for ground probe** |
70-90 m |
120-140 m |
160-190 m |
| Heating Medium Flow |
0.1 l/s |
0.18 l/s |
0.27 l/s |
| Brine Flow |
0.23 l/s |
0.42 l/s |
0.65 l/s |
* Specifications relative to 100%
QN with 1800 operating hours heater and 200 operating
hours hot water at 450 m above sea level
** Stated values are only approximate guide values,
specifications for surface collector with PE-pipe
40 x 2,3.
Solo Heating
Installations recommend NIBE Ground Source Heat
pumps.
Visit
their site for more details

|