NIBE 1145 Ground Source Heat Pumps

Technical Overview


NIBE FIGHTER 1145 is a ground source heat pump for heating single-family homes, multi-family homes and industrial buildings.

NIBE Ground Source Heat Pump

Single Phase

NIBE Fighter 1145 Ground Source Heat Pump

5 KW

8 KW 12 KW
Recorded Capacity* (Brine O /W 35) 1.09 KW 1.73 KW 2.58 KW
Emitted Capacity* (Brine O /W 35) 4.83 KW 8.33 KW 11.88 KW
CoP at Brine 0 /W 35 4.44 CoP 4.82 CoP 4.6 CoP
Height 1475 without adjustable feet (30 - 50mm) 1475 without adjustable feet (30 - 50mm) 1475 without adjustable feet (30 - 50mm)
Width 600mm 600mm 600mm
Depth 625mm 625mm 625mm
Net Weight 140kg 165kg 178kg
Operating Voltage 230 V (1-Phase+N) 230 V (1-Phase+N) 230 V (1-Phase+N)
Intergrated Cartridge Heater 7 (7) KW 7 (7) KW 7 (7) KW
Refrigerant R407C R407C R407C
Ground Heat, hose length** 200-300 m 325-2X250 m 2x250 m-2X350 m
Borehole Depth for ground probe** 70-90 m 120-140 m 160-190 m
Heating Medium Flow 0.1 l/s 0.18 l/s 0.27 l/s
Brine Flow 0.23 l/s 0.42 l/s 0.65 l/s

* Specifications relative to 100% QN with 1800 operating hours heater and 200 operating hours hot water at 450 m above sea level
** Stated values are only approximate guide values, specifications for surface collector with PE-pipe 40 x 2,3.

 

Three Phase

NIBE Fighter 1145 Ground Source Heat Pump

15 KW

17 KW
Recorded Capacity* (Brine O /W 35) 3.27 KW 3.75 KW
Emitted Capacity* (Brine O /W 35) 15.75 KW 17.24 KW
CoP at Brine 0 /W 35 4.81 CoP 4.6 CoP
Height 1475 without adjustable feet (30 - 50mm) 1475 without adjustable feet (30 - 50mm)
Width 600mm 600mm
Depth 625mm 625mm
Net Weight 191kg 199kg
Operating Voltage 3 x 230 V (3-Phase+N) 3 x 230 V (3-Phase+N)
Intergrated Cartridge Heater 9 (9) KW 9 (9) KW
Refrigerant R407C R407C
Ground Heat, hose length** 2 x 300m - 2 x 400m 2 x 350m - 3 x 300m
Borehole Depth for ground probe** 2 x 100m - 2 x 120m 2 x 110m - 2 x 140m
Heating Medium Flow 0.36 l/s 0.40 l/s
Brine Flow 0.75 l/s 0.82 l/s


 

Solo Heating Installations recommend NIBE Ground Source Heat pumps.

Visit their site for more details

NIBE Ground Source Heat Pumps

120 Rectory Lane North, West Malling, Kent, ME19 5HD Tel: 01474 822 701 E-mail: info@soloheatinginstallations.co.uk............